主办:陕西省汽车工程学会
ISSN 1671-7988  CN 61-1394/TH
创刊:1976年

汽车实用技术 ›› 2022, Vol. 48 ›› Issue (4): 137-141.DOI: 10.16638/j.cnki.1671-7988.2023.04.027

• 使用维修 • 上一篇    

电动装载机无法上高压电故障诊断实例分析

温 杰,费孝涛   

  1. 江苏电子信息职业学院 智能交通学院
  • 出版日期:2023-02-28 发布日期:2023-02-28
  • 通讯作者: 温 杰
  • 作者简介:温杰(1983—),男,硕士,讲师,研究方向为车辆智能控制及电控系统故障诊断,E-mail:27173515@qq.com。 通信作者:费孝涛(1988—),男,硕士,讲师,研究方向为车辆智能控制故障诊断,E-mail:1401001@jsei.edu.cn。
  • 基金资助:
    2020 年江苏电子信息职业学院科研青年基金计划项目:基于评价模型的电动公交车再生制动控制策略研究 (KA210805);江苏电子信息职业学院教育科学研究课题:全国新能源汽车技能大赛对高职人才培养促进 作用的实证研究(G3210804);江苏电子信息职业学院“苏电英才”工程以及淮安市自然科学研究项目:分 布式电驱动装载机铲掘工况动力分配研究(HABL202127)。

Analysis of Fault Diagnosis Cases of Electric Loader Unable to Power on High Voltage

WEN Jie, FEI Xiaotao   

  1. Faculty of Intellegent Transportation, Jiangsu Vocational College of Electronics and Information
  • Online:2023-02-28 Published:2023-02-28
  • Contact: WEN Jie

摘要: 电动装载机采用电力驱动,通过高压动力电池向工作电机、行走电机、空调等高压用 电设备供电,具有排放污染低、工作噪音小的优点,已逐步应用于铲装土壤、砂石等散状物 料的工程领域。电动装载机无法上电会导致工作电机和行走电机等高压设备无法工作,文章 以工程作业中电动装载机不能上电的实例,详细分析了故障检测流程,结合电路开展故障排 查。最终找出绝缘故障位置并给出了电动装载机设计上的相关建议。

关键词: 相关建议。 关键词:电动装载机;无法上电;绝缘故障;故障排查

Abstract: The electric loader uses electric drive, through the high voltage power battery to work motor, walking motor, air conditioning and other high voltage electrical equipment power supply. Electric loader has the advantages of low emission pollution, low working noise, has been gradually applied to shovel soil, sand and other loose materials engineering field. The failure of the electric loader to power on will cause the high voltage equipment such as the working motor and the walking motor to fail to work. This article uses an example of the electric loader which cannot be powered on in engineering operations, analyzes the fault detection process in detail, and conducts failure in combination with the circuit. Finally, the location of the insulation failure was found and relevant suggestions on the design of the electric loader were given.

Key words: Electric loader; Unable to power on; Insulation failure; Conducts failure